Feeders: Massachusetts Journeyman Electrician Practice Questions

Feeder ampacity and protection, identification, outside feeders, taps, feeder grounding.
Often missed
Question 1
According to the NEC, the conductors running from the main service panel of a house to a subpanel in a detached garage are:
Question 2
According to the NEC, unless the equipment is listed for 100% operation, feeder conductors must have an ampacity of at least the noncontinuous load plus what percentage of the continuous load?
Question 3
According to the NEC, the rating of a feeder overcurrent device must be at least:
Question 4
According to the informational note in the NEC feeder rules, what voltage drop limits give reasonable efficiency of operation?
Question 5
According to the NEC, when a feeder carries the total load supplied by service conductors with an ampacity of 55 A or less, the feeder ampacity must be:
Question 6
According to the NEC, a common neutral may serve up to how many sets of 3-wire feeders?
Question 7
According to the NEC, when feeders share a common neutral and are installed in a metal raceway, what is required?
Question 8
According to the NEC, before a feeder installation begins, what may the authority having jurisdiction require?
Question 9
According to the NEC, when must a feeder include an equipment grounding conductor?
Question 10
According to the NEC, the equipment grounding conductor run with a feeder is sized based on:
Question 11
According to the NEC, if feeder ungrounded conductors are increased in size to reduce voltage drop, what happens to the wire-type equipment grounding conductor?
Question 12
According to the NEC, when a feeder is run with parallel conductors in two separate raceways, how is the wire-type equipment grounding conductor installed?
Question 13
According to the NEC, is a wire-type equipment grounding conductor ever required to be larger than the circuit conductors supplying the equipment?
Question 14
According to the NEC, where a building has feeders from more than one nominal voltage system, how must the ungrounded feeder conductors be handled?
Question 15
According to the NEC, in a panelboard supplied by a 4-wire delta system with a high leg, which phase position must the high leg occupy?

Ready for the real exam?

Get every question, unlimited calculation practice and timed mock exams in the app.
Coming soon
Download on the App Store
Coming soon
Get it on Google Play
Not affiliated with any state agency, TDLR, PSI, NFPA, EPA or CSLB. NEC® and National Electrical Code® are registered trademarks of NFPA.
Practice questions are written in our own words and cite code sections by number. Always study from your own copy of the code and the official candidate bulletin.
PrivacyTerms
© 2026 Trovyn Tech LLC