Sanitary drainage: Minnesota Journeyworker Plumber Practice Questions

DFU sizing, slope, fittings and changes of direction, cleanouts, sumps and ejectors, backwater valves, indirect waste.
Often missed
Question 1
Under the UPC, what is the standard minimum slope for a 3-inch horizontal drain?
Question 2
Calculation
A 40-ft horizontal drain is laid at 1/4 inch per foot. How much total fall does it have?
Question 3
Calculation
A 4-inch building drain runs 66 ft at 1/8 inch per foot. What is the total fall in feet and inches?
Question 4
Calculation
A slope of 1/4 inch per foot is about what percent grade?
Question 5
Calculation
The invert of a building drain where it leaves the building is at elevation 96.50 ft. The drain runs 80 ft to the sewer tap at 1/8 inch per foot. What is the invert elevation at the tap?
Question 6
Calculation
A sump pump discharges 15 gpm continuously into a gravity drain. Use the code rule of 2 drainage fixture units per gpm of continuous flow. How many DFU does it add?
Question 7
Calculation
Use these values for this problem: lavatory 1 DFU, bathtub 2 DFU, water closet 3 DFU, kitchen sink 2 DFU, clothes washer 3 DFU. A horizontal branch serves 2 lavatories, 1 bathtub and 1 water closet. What is its DFU load?
Question 8
Calculation
Use these values for this problem: a 2-inch horizontal branch may carry up to 6 DFU, a 2-1/2-inch up to 12 DFU, a 3-inch up to 20 DFU (no more than 2 water closets on 3-inch, for this problem). A branch carries 1 water closet (3 DFU), 2 lavatories (1 each), 1 shower (2) and 1 laundry tray (2). What is the smallest branch size?
Question 9
Calculation
Use these values for this problem: at 1/4 inch per foot, a building drain of 3 inches carries up to 42 DFU, 4 inches up to 216 DFU and 5 inches up to 480 DFU. A house has 2 bathroom groups at 6 DFU each, a kitchen sink at 2, a dishwasher at 2, a clothes washer at 3 and a laundry tray at 2. What is the smallest building drain allowed?
Question 10
What is the smallest drain a water closet may discharge into?
Question 11
May a horizontal drain be reduced in size in the direction of flow?
Question 12
How must a drainage stack compare in size with the horizontal branches connected to it?
Question 13
A sanitary tee is used to change direction in a drain. In which direction is this allowed?
Question 14
Which fitting is acceptable at the base of a stack where flow changes from vertical to horizontal?
Question 15
A horizontal drain must turn 90 degrees while staying horizontal. Which fitting choice is correct?

Ready for the real exam?

Get every question, unlimited calculation practice and timed mock exams in the app.
Coming soon
Download on the App Store
Coming soon
Get it on Google Play
Not affiliated with any state agency, TDLR, PSI, NFPA, EPA or CSLB. NEC® and National Electrical Code® are registered trademarks of NFPA.
Practice questions are written in our own words and cite code sections by number. Always study from your own copy of the code and the official candidate bulletin.
PrivacyTerms
© 2026 Trovyn Tech LLC